EXAMPLEA01.SAS--Two sample T-test 13:47 Monday, August 11, 2003 1 WARNING 2: B = 1, so that all tests coincide (univariate case). Since COLLAPSE = 1, power is given as one value with the heading POWER. To print powers with a heading for each test, specify OPT_OFF = {COLLAPSE}. WARNING 10: SIGMA is a scalar. For this program, a scalar SIGMA must equal the variance, NOT the standard deviation. POWER CALCULATION WARNING 22: Power values were rounded to 1 using the value contained in ROUND and should not be be reported as Power = 1. For example, if ROUND = 3 then report Power > 0.999 . This occurred 4 time(s). EXAMPLEA01.SAS--Two sample T-test 13:47 Monday, August 11, 2003 2 ****REQUESTED PRINTED MATRICES*** ESSENCEX 1 0 0 1 BETA 0 1 SIGMA 1 RHO 1 C * BETA * U -1 EXAMPLEA01.SAS--Two sample T-test 13:47 Monday, August 11, 2003 3 ****POWER CALCULATIONS**** ALPHA SIGSCAL BETASCAL TOTAL_N POWER 0.05 0.32 0 20 0.05 0.05 0.32 0.5 20 0.465 0.05 0.32 1 20 0.962 0.05 0.32 1.5 20 1 0.05 0.32 2 20 1 0.05 0.32 2.5 20 1 0.05 1 0 20 0.05 0.05 1 0.5 20 0.185 0.05 1 1 20 0.562 0.05 1 1.5 20 0.887 0.05 1 2 20 0.988 0.05 1 2.5 20 1 0.05 2.05 0 20 0.05 0.05 2.05 0.5 20 0.115 0.05 2.05 1 20 0.315 0.05 2.05 1.5 20 0.601 0.05 2.05 2 20 0.84 0.05 2.05 2.5 20 0.958